The influence of polishing techniques on pre-polymerized CAD\CAM acrylic resin denture bases
Keywords:
CAD\CAM acrylic resin, Acrylic denture base, Polishing, Surface roughness, WettabilityAbstract
Background: Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated.
Objective: The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins.
Methods: This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient.
Results: One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p1<0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001).
Conclusion: Mechanical polishing produced lower surface roughness of CAD\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability.
References
Kuhar, M. and Funduk, N. Effects of Polishing Techniques on the Surface Roughness of Acrylic Denture
Base Resins. J Prosthet Dent. 2005,93(1):76-85, doi: 10.1016/j.prosdent.2004.10.002, PMid: 15624002
Ulusoy M, Ulusoy N, Aydin AK. An evaluation of polishing techniques on surface roughness of acrylic
resins. J Prosthet Dent 1986;56: 107-12. doi: 10.1016/0022-3913(86)90292-1
Vojdani M. Giti R. Polyamide as a Denture Base Material: A Literature Review. J Dent. 2015: 16; 1-9
Consani R.L.X., Pucciarelli R. M. G., Mesquita M.F., Nogueira M.C.F., Barão V.A.R. Polymerization
cycles on hardness and surface gloss of denture bases. International Journal of Contemporary Dental and
Medical Reviews (2014), 6 Pages
Oliveira V.L, Mesquita M.F., Henriques G.E.P., Consani R.L.X., Fragoso W.S. Effect of Polishing
Technique and Brushing on Surface Roughness of Acrylic Resins., J Prosthodont, 2008),17: 308–311, doi:
1111/j.1532-849X.2007.00274.x, PMid: 18086143
Ajaj-ALKordy N.M , Alsaad H.M. Elastic modulus and flexural strength comparisons of high-impact and
traditional denture base acrylic resins The Saudi Dental Journal, 2014; 26: 15–18, doi:
1016/j.sdentj.2013.12.005, PMid: 24532960, PMCid: PMC3924576
Ruyter IE, Svendsen SA. Flexural properties of denture base polymers. J Prosthet Dent 1980; 43: 95-104.
doi: 10.1016/0022-3913(80)90362-5
Pusz A., Michalik. M.S. Topography and the structure of the surface of polyamide - glass composites after
the ageing process. Journal of Achievements in Materials and Manufacturing Engineering, 2011: 44; 1
Goncalves, T.S., Spohr, A.M., de Souza, R.M., Macedo de Menezes, L. Surface roughness of auto
polymerized acrylic resinaccording to different manipulation and polishing methods: an in situ evaluation.
Angle Orthod. 2008; 78, 931–934. doi: 10.2319/080307-363.1, PMid: 18298208
Braun, K.O., Mello, J.A.N., Rached, R.N., Del Bel Cury, A.A., Surface texture and some properties of
acrylic resins submitted to chemical polishing. J. Oral Rehabil. 2003; 30, 91–98. doi: 10.1046/j.1365- 2842.2003.00997.x, PMid: 12485391
Sofou, A., Emmanouil, J., Peutzfeldt, A., Owall, B. The effect of different polishing techniques on the
surface roughness of acrylic resin materials. Eur. J. Prosthodont. Restor. Dent. 2001; 9, 117–122. PMid:
Al-Rifaiy, M.Q. The effect of mechanical and chemical polishing techniques on the surface roughness of
denture base acrylic resins. Saudi Dental J. 2010; 22, 13–17. doi: 10.1016/j.sdentj.2009.12.006, PMid:
, PMCid: PMC3723273
Braun, K.O., Mello, J.A.N., Rached, R.N., Del Bel Cury, A.A. Surface texture and some properties of
acrylic resins submitted to chemical polishing. J. Oral Rehabil. 2003; 30, 91–98. doi: 10.1046/j.1365- 2842.2003.00997.x, PMid: 12485391
Rahal, J.S., Mesquita, M.F., Henriques, G.E., Nobilo, M.A. Surface roughness of acrylic resins submitted
to mechanical and chemical polishing. J. Oral Rehabil. 2004; 31, 1075–1079. doi: 10.1111/j.1365- 2842.2004.01344.x, PMid: 15525385
Kattadiyil M., Goodacre Ch.J. Baba N.Z. CAD/CAM Complete Dentures: A Review of Two Commercial
Fabrication Systems .California Dental Association (CDA) Journal, 2013; l41: 6.
Amin M., Akbar M. Amin S.: Hydrophobicity of silicone rubber used for outdoor insulation (An overview)
Rev. Adv. Mater. Sci. ,2007; 16; 10-26
Hilgenberg S.P., Orellana-Jimenez E.E., Sepúlveda-Navarro W.F., Arana-Correa B.E., Alves T.D.C.,
Campanha N.H. : Evaluation of surface physical properties of acrylic resins for provisional prosthesis.
Mat. Res. 2008; 11:3
Hanieh M., Ehsan F., Mitra F., Amir K.AR. The Effect of mouthwashes on the flexural strength of interim
restorative materials. OHDM; 2016, 15:3
Lamb DJ, Ellis B, and Priestley D. The effects of process variables on levels of residual monomer in
autopolymerizing dental acrylic resin. J Dent. 1983; 11 (1): 80-88, doi: 10.1016/0300-5712(83)90051-9
Bollen C.M.L., Lambrechts P., Quirynen M. Comparison of surface roughness of oral hard materials to the
threshold surface roughness for bacterial plaque retention: a review of literature. Dent. Mater.
;13:258–269, doi: 10.1016/S0109-5641(97)80038-3
Radford D.R., Challacombe S.J., Walter J.D. Denture plaque and adherence of Candida albicans to denture
base materials in vivo and in vitro. Crit. Rev. Oral Biol. Med. 1999;10:99–116, doi:
1177/10454411990100010501, PMid: 10759429
Baba N.Z Materials and Processes for CAD/CAM Complete Denture Fabrication. Curr Oral Health Rep.
;3:203–208, doi: 10.1007/s40496-016-0101-3
Kattadiyil MT, Goodacre CJ, Baba NZ: CAD CAM complete dentures: a review of two commercial
fabrication systems. J. California Dent Association, 2013; 41:407–416. PMid: 23875432
Kondo Y, Tomohiro Takagaki T., Okuda M., Ikeda M., Kadoma Y., Yamauchi J., et al. Effect of
PMMA filler particles addition on the physical properties of resin Composite. Dental Materials Journal
; 29(5): 596–601, doi: 10.4012/dmj.2009-141, PMid: 20834188
Menzies L. K., Jones W.L. The Impact of Contact Angle on the Biocompatibility of Biomaterials.
Optometry and Vision Science, 2010; 87(6):387-99, doi: 10.1097/OPX.0b013e3181da863e
Jones W.D. Hall C.G., Sutow J.E. Robertson N.K. Chemical and molecular weight analyses of
Prosthodontic soft polymers. Journal of Dental Research, 1991; 70 (5): 874-9, doi:
1177/00220345910700050201, PMid: 2022770
Published
Issue
Section
License
Copyright (c) 2020 KNOWLEDGE KINGDOM PUBLISHING
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.