Effect of diode laser irradiation on compressive strength of dental amalgam

Authors

  • Mahtab Hamzeh DDS, Pedodontist, Assistant Professor, Dental Research Center, Faculty of Dentistry, Babol University of Medical Sciences, Babol, Iran

Keywords:

Compressive strength, Dental amalgam, Diode laser

Abstract

Introduction: One of the biggest disadvantages of dental amalgam is that gaining its ultimate strength is a slow process. The use of a rapid-setting amalgam with high early compressive strength could be a better option in preventing   early fractures in pediatric dentistry. The aim of this study was to determine the effect of diode laser irradiation on compressive strength of dental amalgam. 

Methods: A case-control study was performed on 180 amalgam samples made at the Tehran Dental Material Research Center in 2014. Fifteen and thirty minute compressive strength of regular setting and fast setting amalgams were measured as control. In case groups, the samples were irradiated by 810nm diode laser with power of 1 and 2 watt and in pulsed and continuous mode, and compressive strength was measured after 15 and 30 minutes. Statistical analysis was performed with SPSS 18 using one and two way ANOVA and Scheffe multiple comparisons test and p<0.05 was considered significant.

Results: Numerous kinds of laser irradiation led to a significant increase in compressive strength compared to regular setting control groups. Fifteen minutes-compressive strength of regular-setting amalgam irradiated by 2 watt laser was significantly more than fast-setting control group (p<0.05).

Conclusion: Irradiation by 810nm diode laser can significantly increase the compressive strength of dental amalgam especially in the first 15 minutes.

References

Mcdonald RE, Avery DR, Dean JA. Dentistry for the Child and Adolescent. 9th ed. 205-14. St. Louis,

Missouri: Mosby Inc. 2012.

Pinkham JR, Casamassimo PS, McTigue DJ, Fields HW, Nowak AJ. Pediatric Dentistry Infancy Through

Adolescence. 4th ed. 325-40. St Louis, Missouri: Elsevier Inc. 2005.

Bharti R, Wadhwani KK, Tikku AP, Chandra A. Dental amalgam: an update. J Conserv Dent. 2010; 13(4):

-8. doi: 10.4103/0972-0707.73380. PMID: 21217947, PMCID: PMC3010024.

Fathi M, Mortazavi V. A review on dental amalgam corrosion and its consequences. J Res Med Sci. 2004;

(1): 42-51.

Darvell BW. Development of strength in dental silver amalgam. Dent Mater. 2012; 28(10): e207-17. doi:

1016/j.dental.2012.05.002. PMID: 22677140.

Sakaguchi RL, Powers JM. Craig’s Restorative Dental Matrerial. 13th ed. 83-104. 200-38. Phildelphia, PA:

Elsevier Inc. 2012.

Grum G. Comparison of different techniques of laser surface hardening. J Ach in Mat Manuf Eng 2007;

(1): 17-25.

Surzhenkov A, Kulu P, Viljus M, Vallikivi A, Latokartano J. Microstructure and wear resistance of the

laser hardened PM tool steel vanadis 6. J Mat Sci. 2010; 148(2): 22-8.

Chen KW, Jeng JH, Lin CP, Wu PH, Lan WH. Thermal changes of dentin during CO2 lasing. Chin Dent J.

; 18(1): 1-8.

Beer F, Korpert W, Passow H, Sleidler A, Meinl A, Buchmair AG, et al. Reduction of collateral thermal

impact of diode laser irradiation on soft tissue due to modified application parameters. Laser med Sci.

; 27(5): 917-21. doi: 10.1007/s10103-011-1007-x.

Choi B, Welch AJ. Analysis of thermal relaxation during laser irradiation of tissue. Laser Surg Med. 2001;

(4): 351-9. doi: 10.1002/lsm.1128. PMID: 11746113.

Suleiman M, Rees JS, Addy M. Surface and pulp chamber temperature rises during bleaching using a diode

laser: A study in vitro. Br Dent J. 2006; 200(11): 631-4. doi: 10.1038/sj.bdj.4813644. PMID: 16767142.

Almuslet N, Elamin HJ, Elbashir BO. Hardness enhancement of amalgam teeth fillings using diode laser

(675 nm). Journal of Analytical Science and Technology 2011; 2(2): 64-8. doi: 10.5355/JAST.2011.64.

Published

2022-01-18

Issue

Section

Articles